DocumentCode
739863
Title
A Coaxial Time Constant Standard for the Determination of Phase Angle Errors of Current Shunts
Author
Pan, Xianlin ; Zhang, Jiangtao ; Ma, Xuefeng ; Gu, Yang ; Liu, Wenfang ; Wang, Biao ; Lu, Zuliang ; Zhang, Deshi
Author_Institution
Harbin Inst. of Technol., Harbin, China
Volume
62
Issue
1
fYear
2013
Firstpage
199
Lastpage
204
Abstract
This paper describes a new method to determine the phase angle errors of ac shunts by measuring the inductance and distributed capacitance. A 1-Ω shunt of coaxial design has been developed as the time constant standard. A coaxial inductor with identical structure as the time constant standard has been developed. A four-terminal mutual inductor has also been built for the measurement of the inductance of the time constant standard. The method is based on the use of a binary inductive current divider to compare the inductor with the mutual inductor. The standard uncertainty of the inductance measurement of the time constant standard is within 28 pH at frequencies up to 200 kHz. The expanded uncertainty of the phase angle errors is from 0.4 μrad at 1 kHz to 80.0 μrad at 200 kHz at 1 A.
Keywords
capacitance measurement; inductance measurement; inductors; AC shunts; binary inductive current divider; coaxial design; coaxial time constant standard; current 1 A; current shunts; distributed capacitance measurement; four-terminal mutual inductor; frequency 1 kHz; frequency 200 kHz; inductance measurement; phase angle error determination; Current measurement; Frequency measurement; Inductance; Inductors; Shunt (electrical); Standards; Uncertainty; Binary inductive current divider (BICD); current shunt; four-terminal mutual inductor; residual inductance; substitution method; time constant;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.2012.2212595
Filename
6289364
Link To Document