Abstract :
Objective: To develop a pipeline for realistic head models of nonhuman primates (NHPs) for simulations of noninvasive brain stimulation, and use these models together with empirical threshold measurements to demonstrate that the models capture individual anatomical variability. Methods: Based on structural MRI data, we created models of the electric field (E-field) induced by right unilateral (RUL) electroconvulsive therapy (ECT) in four rhesus macaques. Individual motor threshold (MT) was measured with transcranial electric stimulation (TES) administered through the RUL electrodes in the same subjects. Results: The interindividual anatomical differences resulted in 57% variation in median E-field strength in the brain at fixed stimulus current amplitude. Individualization of the stimulus current by MT reduced the E-field variation in the target motor area by 27%. There was significant correlation between the measured MT and the ratio of simulated electrode current and E-field strength (r2 = 0.95, p = 0.026). Exploratory analysis revealed significant correlations of this ratio with anatomical parameters including of the superior electrode-to-cortex distance, vertex-to-cortex distance, and brain volume (r2 > 0.96, p <; 0.02). The neural activation threshold was estimated to be 0.45 ± 0.07 V/cm for 0.2-ms stimulus pulse width. Conclusion: These results suggest that our individual-specific NHP E-field models appropriately capture individual anatomical variability relevant to the dosing of TES/ECT. These findings are exploratory due to the small number of subjects. Significance: This study can contribute insight in NHP studies of ECT and other brain stimulation interventions, help link the results to clinical studies, and ultimately lead to more rational brain stimulation dosing paradigms.
Keywords :
biomedical MRI; biomedical electrodes; brain; medical signal processing; neurophysiology; patient treatment; transcranial magnetic stimulation; E-field strength; E-field variation; NHP E-field models; RUL electrodes; TES-ECT dosing; brain volume; electric field model; electrode-cortex distance; empirical threshold measurements; individual motor threshold; interindividual anatomical differences; median E-field strength; model capture individual anatomical variability; neural activation threshold; noninvasive brain stimulation; rational brain stimulation dosing paradigms; realistic head models; rhesus macaques; right unilateral electroconvulsive therapy; simulated electrode current; stimulus current amplitude; stimulus pulse width; structural MRI data; target motor area; transcranial electric stimulation; vertex-cortex distance; Brain modeling; Conductivity; Electrodes; Finite element analysis; Head; Magnetic resonance imaging; Tensile stress; Electric field model; electroconvulsive therapy; finite element method; magnetic resonance imaging; motor threshold; nonhuman primate; transcranial electric stimulation;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2015.2425406
Filename :
7091878
Link To Document :
بازگشت