Title :
Experimental Evaluation of an Invasive Medical Instrument Based on a Displacement Measurement System
Author :
Fotiadis, Dimitris A. ; Astaras, Alexandros ; Bamidis, Panagiotis D. ; Papathanasiou, Kostas ; Kalfas, Anestis
Author_Institution :
Sch. of Med., Aristotle Univ. of Thessaloniki, Thessaloniki, Greece
Abstract :
This paper presents a novel method for tracking the position of a medical instrument´s tip. The system is based on phase locking a high frequency signal transmitted from the medical instrument´s tip to a reference signal. Displacement measurement is established having the loop open, in order to get a low frequency voltage representing the medical instrument´s movement; therefore, positioning is established by means of conventional measuring techniques. The voltage-controlled oscillator stage of the phase-locked loop (PLL), combined to an appropriate antenna, comprises the associated transmitter located inside the medical instrument tip. All the other low frequency PLL components, low noise amplifier and mixer, are located outside the human body, forming the receiver part of the system. The operating details of the proposed system were coded in Verilog-AMS. Simulation results indicate robust medical instrument tracking in 1-D. Experimental evaluation of the proposed position tracking system is also presented. The experiments described in this paper are based on a transmitter moving opposite a stationary receiver performing either constant velocity or uniformly accelerated movement, and also together with two stationary receivers performing constant velocity movement again. This latter setup is implemented in order to demonstrate the prototype´s accuracy for planar (2-D) motion measurements. Error analysis and time-domain analysis are presented for system performance characterization. Furthermore, preliminary experimental assessment using a saline solution container to more closely approximate the human body as a radio frequency wave transmission medium has proved the system´s capability of operating underneath the skin.
Keywords :
biomedical equipment; biomedical measurement; displacement measurement; low noise amplifiers; motion measurement; phase locked loops; skin; tracking; 2D planar motion measurements; antenna; displacement measurement system; error analysis; high frequency signal transmission; invasive medical instrument; low frequency PLL components; low frequency voltage; low noise amplifier; phase-locked loop; position tracking system; radiofrequency wave transmission medium; saline solution container; skin; time-domain analysis; voltage-controlled oscillator stage; Accuracy; Biomedical measurement; Displacement measurement; Instruments; Receivers; Transmitters; Voltage-controlled oscillators; Displacement measurement; RF; medical instrument; phase shift; position tracking; radio frequency (RF);
Journal_Title :
Biomedical and Health Informatics, IEEE Journal of
DOI :