Abstract :
Goal: The goal of this study is to present a modified pulse contour method to estimate the stroke volume (SV) based on an oscillometric sphygmomanometer. Methods: The pulse contour was extracted from the pulse signal of the cuff pressure. The characteristics of the brachial artery, as well as the compliance (Cartery) and time constant τ of the Windkessel model, could be determined and used to estimate the SV once the apparatus finished the blood pressure measurement. Results: Assessments of the SV by echocardiography and our method were carried out in 55 subjects. The change in the brachial arterial volume obtained by our method was significantly correlated with that of the two-dimensional ultrasound method (rv = 0.871). The estimated SV values by our method for male and female groups, SVestimate, were also significantly correlated with the echocardiography results, SVref (rmale = 0.680, rfemale = 0.706). The Bland-Altman plot showed agreement between SVref and SVestimate, with all data points contained within the limits of agreement (± 2 SD). The mean difference and standard deviation (mean ± SD) were 0.101 ± 14.880 ml and 0.650 ± 11.990 ml for the male and female groups, respectively. Conclusion: The blood pressure, SV, and cardiac output were measured simultaneously, making our method well suited for home use. Significance: Our method was embedded in an oscillometric sphygmomanometer.
Keywords :
blood; blood pressure measurement; blood vessels; echocardiography; medical image processing; Bland-Altman plot; Windkessel model; arterial characteristics; blood pressure measurement; brachial artery; brachial blood pressure; cardiac output; cuff pressure; echocardiography; extracted pulse contour; modified pulse contour method; oscillometric sphygmomanometer; pulse signal; standard deviation; stroke volume assessment; two-dimensional ultrasound method; Arteries; Biomedical measurement; Blood pressure; Brachytherapy; Computational modeling; Mercury (metals); Pressure measurement; Brachial artery; Stroke volume; brachial artery; oscillometry; pulse contour; stroke volume (SV);
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2015.2412136
Filename :
7063957
Link To Document :
بازگشت