Abstract
This paper shows a new possibility for quality and reliability testing of low-current contacts by nonlinearity measuring. A normal third harmonic distortion (THD) tester cannot be used for low-impedance elements. Therefore, a special variant of the THD tester is described for this aim. This method was proved at a set of relay contacts and the results of testing validate a propriety of proposed method.
Keywords
electrical contacts; harmonic distortion; reliability; THD tester; contact reliability; contact voltage; low-current contact; quality testing; reliability testing; third harmonic distortion; Cutoff frequency; Distortion measurement; Dynamic range; Harmonic distortion; Impedance; Power harmonic filters; Relays; Resistors; Testing; Voltage; Contact; THD-meter; reliability; third harmonic distortion (THD);