Abstract
The authors report the first comparison, at the national standards level, of photodiode frequency response measurements at wavelengths of 1.285, 1.319 and 1.531 μm. A photodiode was measured up to 40 GHz and the results were normalised to 1.319 μm using a model of the device. The average scatter in the results was ±0.12 dB (2σ) below 20 GHz and ±0.21 dB from 20 to 33 GHz
Keywords
electric variables measurement; frequency response; measurement standards; microwave measurement; millimetre wave measurement; photodiodes; semiconductor device testing; standardisation; 1.285 to 1.531 micron; 40 GHz; NIST; NPE; frequency response measurements; model; national standards level; photodiode frequency response;