  • Abstract
    This work develops a class of ultrasound phase aberration correction/autofocusing algorithms that are based upon the properties of the covariance matrix of the channel signals for time-delay focused resolution/speckle cells. The scaled covariance matrix SCM algorithms are designed to blindly estimate and correct focusing timing errors due to thin layers of unanticipated fatty tissue located in the near field of the transducer array. An important aspect of the algorithm is that the scaling of the covariance matrix elements fundamentally establishes a channel independent phase reference relative to which the aberrant channel phases are estimated. The model development involved the combination of a rigorous mathematical analysis of the scattering of ultrasound in random scattering media and extensive statistical simulation studies with phase aberrations imposed upon both the transmit and received channel signals. Under the assumption of a near field aberration model, the statistical simulation analyses showed that the SCM algorithms in simulation are capable of accurately estimating relative time delay channel errors with RMS timing errors up to /spl sim/62 ns, with interchannel correlation lengths as short as 1.4 mm.
  • Keywords
    biomedical ultrasonics; covariance matrices; delays; ultrasonic focusing; RMS timing errors; aberrant channel phases; autofocusing; channel independent phase reference; channel signals; covariance matrix elements; fatty tissue; focusing timing errors; medical ultrasound; random scattering media; relative time delay channel errors; scaled covariance matrix; scaled covariance matrix algorithm; time-delay focused resolution/speckle cells; ultrasound phase aberration correction/autofocusing algorithms; Algorithm design and analysis; Analytical models; Covariance matrix; Error correction; Scattering; Signal resolution; Speckle; Timing; Ultrasonic imaging; Ultrasonic transducers; Algorithms; Computer Simulation; Image Enhancement; Image Interpretation, Computer-Assisted; Quality Control; Regression Analysis; Reproducibility of Results; Scattering, Radiation; Sensitivity and Specificity; Ultrasonography;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2003.1214500
  • Filename
    1214500