DocumentCode :
747660
Title :
Determination of DC voltage ratio of a self-calibrating DC voltage divider
Author :
Liu, Ling Xiang ; Chua, Sze Wey ; Ang, Chee Kiang
Author_Institution :
Electr. Metrol. Dept., Nat. Metrol. Center, Singapore, Singapore
Volume :
54
Issue :
2
fYear :
2005
fDate :
4/1/2005 12:00:00 AM
Firstpage :
571
Lastpage :
575
Abstract :
This paper presents two techniques for determining the ratios of resistive dc voltage dividers up to 1 kV. The techniques are based on absolute calibration methods. The setup requires equipment commonly available in most standard laboratories and is capable of providing high-accuracy calibration under practical laboratory working conditions.
Keywords :
calibration; constants; laboratory techniques; voltage dividers; absolute calibration; dc voltage ratio; high-accuracy calibration; laboratory working conditions; resistive dc voltage dividers; self-calibrating dc voltage divider; Calibration; Circuit testing; Detectors; Employee welfare; Laboratories; Measurement standards; Metrology; Productivity; Switches; Voltage measurement; Calibration; dc voltage; dc voltage ratio; self-calibrating divider;