DocumentCode :
749650
Title :
Twin shaping filter techniques to compensate the signals from CZT/CdTe detectors
Author :
Auricchio, Natalia ; Amati, Lorenzo ; Basili, Angelo ; Caroli, Ezio ; Donati, Ariano ; Franceschini, Turiddo ; Frontera, Filippo ; Landini, Gianni ; Roggio, Antonella ; Schiavone, Filomena ; Stephen, John Buchan ; Ventura, Giulio
Author_Institution :
IASF/CNR, Bologna, Italy
Volume :
52
Issue :
5
fYear :
2005
Firstpage :
1982
Lastpage :
1988
Abstract :
A Gamma Ray Burst Monitor (GRBM) has been proposed to form part of the LOBSTER experiment, approved by ESA for a Phase A study for a future flight (2009) aboard the International Space Station (ISS). The GRBM detector would be based on CdZnTe array modules, maintained, together with the front-end electronics, at a temperature of about 250 K by using Peltier effect or passive cooling systems. To improve the detector performance several hardware (HW) and software (SW) techniques are being tested. In addition to the strip readout technique for rejecting charged particles interacting with the detector, we have investigated a method which employs a pair of active filters (one slow and one fast) to analyze differently shaped signals from the same charge sensitive preamplifier. This technique could be particularly useful for application with multi-element detection systems requiring dedicated front end and readout integrated circuits (ASICs) especially designed for the implementation of the HW correction procedure. Some experimental results are presented from the application of the biparametric technique on CdZnTe/CdTe detectors with planar and segmented electrodes in order to study the influence of the correction parameters and to verify the efficiency of the correction algorithm on groups of neighboring pixels.
Keywords :
active filters; application specific integrated circuits; gamma-ray astronomy; gamma-ray bursts; high energy physics instrumentation computing; nuclear electronics; preamplifiers; readout electronics; semiconductor counters; ASIC; CZT/CdTe detectors; CdZnTe array modules; ESA; GRBM detector; Gamma Ray Burst Monitor; ISS; International Space Station; LOBSTER experiment; Peltier effect; active filters; application specific integrated circuit; biparametric technique; charge sensitive preamplifier; charged particle interaction; front-end electronics; hard X-ray; hardware techniques; multielement detection systems; passive cooling systems; pixels; planar electrodes; readout integrated circuits; segmented electrodes; shaped signals; signal compensation technique; software techniques; strip readout technique; twin shaping filter techniques; Active filters; Aerospace electronics; Detectors; Electronics cooling; Gamma ray bursts; International Space Station; Monitoring; Sensor arrays; Temperature; Thermoelectricity; CdZnTe detector; hard X and; shaping filters spectroscopy; signal compensation technique;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2005.856884
Filename :
1546540
Link To Document :
بازگشت