• DocumentCode
    750187
  • Title

    Development and characterisation of tissue equivalent materials for frequency range 30-300MHz

  • Author

    Peyman, A. ; Gabriel, C.

  • Volume
    43
  • Issue
    5
  • fYear
    2007
  • Firstpage
    19
  • Lastpage
    20
  • Abstract
    Two formulations for tissue equivalent liquids are presented and characterised in terms of dielectric properties in the frequency range 30-300 MHz. The purpose is to provide viable options for consideration by the standardisation bodies dealing with the assessment of exposure to electromagnetic sources in that frequency range
  • Keywords
    biological effects of fields; dielectric liquids; electrical conductivity; permittivity; 20 C; 30 to 300 MHz; VHF; diacetin based solutions; dielectric properties; electromagnetic sources; sucrose based solutions; tissue equivalent materials;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:20073455
  • Filename
    4137465