  • Title

    Watthour meter accuracy under controlled unbalanced harmonic voltage and current conditions

  • Author

    Domijan, A., Jr. ; Embriz-Santander, E. ; Gilani, A. ; Lamer, G. ; Stiles, C. ; Williams, C.W., Jr.

  • Author_Institution
    Dept. of Electr. Eng., Florida Univ., Gainesville, FL, USA
  • Volume
    11
  • Issue
    1
  • fYear
    1996
  • fDate
    1/1/1996 12:00:00 AM
  • Firstpage
    64
  • Lastpage
    72
  • Abstract
    This work presents the results of phase I of the project on the accuracy of watthour meters when subjected to closely-duplicated real-world unbalanced harmonic voltage and current conditions. Such real-world conditions involved differences in voltage and current magnitudes as well as differences in the voltage and current total harmonic distortion levels of each phase. Tests were performed on a selected sample of nine three-phase and three single-phase watthour meters. Some results showed that under a particular set of unbalanced waveforms with harmonic conditions of ITHD>80% and VTHD>2%, the percentage errors exhibited by these meters ranged from -10.09% to +0.52%
  • Keywords
    computerised instrumentation; harmonic distortion; monitoring; power system harmonics; power system measurement; testing; watthour meters; controlled unbalanced harmonic voltage; harmonic conditions; single-phase watthour meters; three-phase watthour meters; total harmonic distortion levels; unbalanced harmonic current; unbalanced harmonic voltage; unbalanced waveforms; watthour meter accuracy; Flexible printed circuits; Performance evaluation; Power measurement; Power quality; Power system harmonics; Reactive power; Testing; Total harmonic distortion; Voltage control; Watthour meters;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/61.484002
  • Filename
    484002