DocumentCode
750880
Title
Magnetic field-induced currents in the human body in proximity of power lines
Author
Stuchly, Maria A. ; Zhao, Shengkai
Author_Institution
Dept. of Electr. & Comput. Eng., Victoria Univ., BC, Canada
Volume
11
Issue
1
fYear
1996
fDate
1/1/1996 12:00:00 AM
Firstpage
102
Lastpage
109
Abstract
Electric currents induced due to 60 Hz magnetic fields in a human body placed in close proximity to various high voltage transmission lines are computed. A realistic model of the human body from the anatomical and electrical point of view with resolution of 1.3 cm for the body and 0.665 cm for the head is used. The computations are performed using the impedance method. Three representative configurations of high voltage transmission lines, namely 500 kV, 138 kV and 25 kV are analyzed. The results indicate that the maximum current densities of the order of 0.2 μA/cm2 can be induced in a lineman working on a 500 kV line (0.5 m away from closest conductors). A good correlation can be seen between the computed magnetic field in the location of the human body and the induced current densities. The induced currents computed here and estimated from measured magnetic fields in various power line environments are compared to those for typical home and office exposures, including appliances
Keywords
biological effects of fields; current density; electric impedance; health hazards; magnetic fields; power transmission lines; 0.5 m; 138 kV; 25 kV; 500 kV; 60 Hz; electric currents; head; high voltage transmission lines; human body; impedance method; induced current densities; lineman; magnetic field-induced currents; power lines; Biological system modeling; Current density; Humans; Impedance measurement; Magnetic analysis; Magnetic field measurement; Magnetic fields; Magnetic heads; Power transmission lines; Voltage;
fLanguage
English
Journal_Title
Power Delivery, IEEE Transactions on
Publisher
ieee
ISSN
0885-8977
Type
jour
DOI
10.1109/61.484005
Filename
484005
Link To Document