Abstract :
The authors comment on the paper by L.U. Gokdere et al. (see ibid., vol. 48, p.870-2, 2001). A review of the experimental evidence shows that passivity-based control of saturated induction motors does not provide superior performance over input-ouput linearization. Higher tracking errors can be observed and traced to the open-loop nature of the flux controller. In contrast, input-output linearization controllers achieve close tracking of flux, speed, and position references for the most demanding trajectories.
Keywords :
induction motors; machine control; magnetic flux; magnetic variables control; close flux tracking; flux controller; input-ouput linearization; input-output linearization controllers; open-loop nature; passivity-based control; position references; saturated induction motors; tracking errors; Current measurement; Filtering; Induction motors; Open loop systems; Position control; Pulse width modulation inverters; Stators; Steady-state; Torque; Voltage;