Abstract :
This paper presents a step-by-step system identification approach to estimate the parameters of a three-phase salient-pole synchronous machine rated at 5 kVA from online small disturbance responses. The machine equivalent circuit model linear parameters and the nonlinear saturated parameters are estimated. The estimation is performed using the maximum likelihood algorithm. Simulation studies based on the online measured small and large dynamic disturbances are performed to validate the accuracy of the identified machine model including the saturation
Keywords :
equivalent circuits; machine theory; maximum likelihood estimation; probability; synchronous machines; 500 kVA; accuracy; equivalent circuit model; linear parameters; maximum likelihood algorithm; nonlinear saturated parameters; parameter estimation; saturation; simulation; small disturbance response; system identification; three-phase salient-pole synchronous machine; Circuit simulation; Equivalent circuits; Maximum likelihood estimation; Parameter estimation; Performance evaluation; Samarium; State estimation; Synchronous machines; System testing; Time domain analysis;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/60.372565
Filename :
372565
Link To Document :
بازگشت