• DocumentCode
    753991
  • Title

    Comparison of Conventional Filtering and Independent Component Analysis for Artifact Reduction in Simultaneous Gastric EMG and Magnetogastrography From Porcines

  • Author

    Irimia, Andrei ; Richards, William O. ; Bradshaw, L. Alan

  • Author_Institution
    Dept. of Radiol., Univ. of California at San Diego, La Jolla, CA, USA
  • Volume
    56
  • Issue
    11
  • fYear
    2009
  • Firstpage
    2611
  • Lastpage
    2618
  • Abstract
    In this study, we perform a comparative study of independent component analysis (ICA) and conventional filtering (CF) for the purpose of artifact reduction from simultaneous gastric EMG and magnetogastrography (MGG). EMG/MGG data were acquired from ten anesthetized pigs by obtaining simultaneous recordings using serosal electrodes (EMG) as well as with a superconducting quantum interference device biomagnetometer (MGG). The analysis of MGG waveforms using ICA and CF indicates that ICA is superior to the CF method in its ability to extract respiration and cardiac artifacts from MGG recordings. A signal frequency analysis of ICAand CF-processed data was also undertaken using waterfall plots, and it was determined that the two methods produce qualitatively comparable results. Through the use of simultaneous EMG/MGG, we were able to demonstrate the accuracy and trustworthiness of our results by comparison and cross-validation within the framework of a porcine model.
  • Keywords
    SQUID magnetometers; biomagnetism; electromyography; independent component analysis; medical signal processing; physiological models; MGG recordings; anesthetized pigs; cardiac artifact; conventional filtering; extract respiration artifact; independent component analysis; magnetogastrography; porcine model; porcines; serosal electrodes; signal frequency analysis; simultaneous gastric EMG; superconducting quantum interference device biomagnetometer; Electrodes; Electromyography; Filtering; Independent component analysis; Interference; Magnetic separation; SQUIDs; Superconducting devices; Superconducting filters; Superconducting magnets; Artifact; EMG; filter; independent component analysis (ICA); magnetogastrography (MGG); Algorithms; Animals; Artifacts; Data Interpretation, Statistical; Electromagnetic Fields; Electromyography; Gastrointestinal Motility; Signal Processing, Computer-Assisted; Swine;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2009.2020694
  • Filename