Title :
High-efficiency drive due to power factor control of a permanent magnet synchronous motor
Author :
Nakamura, Yoshinobu ; Kudo, Toshiaki ; Ishibashi, Fuminori ; Hibino, Sadayoshi
Author_Institution :
Toshiba Corp., Mie, Japan
fDate :
3/1/1995 12:00:00 AM
Abstract :
A drive system of a permanent magnet motor without a magnetic position detector is described. Generally, the position data of a magnet is obtained from the terminal voltage of the motor. In the newly developed method, the inverter DC-link current waveform provides the control signal for driving a permanent magnet motor without a detector. Since the power factor of the motor is controlled around 1.0, the motor runs at a higher efficiency than one controlled by the conventional method. Therefore, this control method saves energy. Current pulsation induced by sudden load fluctuations has been studied and its stabilization has been achieved. This paper provides the principle and operation of the new control method, simulated characteristics, and experimental results
Keywords :
DC-AC power convertors; invertors; machine control; permanent magnet motors; power control; synchronous motor drives; control signal; current pulsation; energy saving; high-efficiency drive; inverter DC-link current waveform; magnet position data; permanent magnet synchronous motor; power factor control; sudden load fluctuations; terminal voltage; Brushless DC motors; DC motors; Magnetic separation; Permanent magnet motors; Pulse width modulation inverters; Reactive power; Rotors; Servomotors; Synchronous motors; Voltage;
Journal_Title :
Power Electronics, IEEE Transactions on