DocumentCode
754331
Title
Calibrating a triaxial accelerometer-magnetometer - using robotic actuation for sensor reorientation during data collection
Author
Renk, Erin L. ; Rizzo, Matthew ; Collins, Walter ; Lee, Fuju ; Bernstein, Dennis S.
Author_Institution
The Aerosp. Corp., El Segundo, CA, USA
Volume
25
Issue
6
fYear
2005
fDate
12/1/2005 12:00:00 AM
Firstpage
86
Lastpage
95
Abstract
A kinematic model and kinematic maneuver to calibrate a triaxial accelerometer and magnetometer was derived. The calibration was accomplished by implementing the maneuver on a six-degrees-of-freedom robotic arm. Analysis of the accuracy of the experimental results was performed by generating simulated data and formulating two least-squares optimization problems. By first calibrating the accelerometers with simulated data, the possibility of inconsistency in the estimator was evaluated. By calibrating the accelerator and the magnetometer separately, discrepancies in the data and model were checked. The simultaneous calibrations produced smaller errors for both the magnetometer and accelerometer compared to the separate calibrations.
Keywords
accelerometers; calibration; least squares approximations; magnetometers; manipulator kinematics; optimisation; calibration; data collection; kinematic maneuver; kinematic model; least-squares optimization; robotic actuation; sensor reorientation; six-degrees-of-freedom robotic arm; triaxial accelerometer-magnetometer; Accelerator magnets; Accelerometers; Analytical models; Calibration; Kinematics; Magnetic analysis; Magnetic sensors; Magnetometers; Performance analysis; Robot sensing systems;
fLanguage
English
Journal_Title
Control Systems, IEEE
Publisher
ieee
ISSN
1066-033X
Type
jour
DOI
10.1109/MCS.2005.1550155
Filename
1550155