• DocumentCode
    756213
  • Title

    On EMG Signal Compression With Recurrent Patterns

  • Author

    Filho, Eddie B L ; Silva, Eduardo A B da ; De Carvalho, Murilo B.

  • Author_Institution
    Centro de Cienc. Tecnol. e Inovacao do Polo Ind. de Manaus, Manaus
  • Volume
    55
  • Issue
    7
  • fYear
    2008
  • fDate
    7/1/2008 12:00:00 AM
  • Firstpage
    1920
  • Lastpage
    1923
  • Abstract
    In this paper, the multidimensional multiscale parser (MMP) is employed for encoding electromyographic signals. The experiments were carried out with real signals acquired in laboratory and show that the proposed scheme is effective, outperforming even wavelet-based state-of- the-art schemes present in the literature in terms of percent root mean square difference times compression ratio.
  • Keywords
    data compression; electromyography; medical signal processing; EMG signal compression; compression ratio; electromyography; isometric contractions; multidimensional multiscale parser; recurrent patterns; root mean square difference; Data compression; Dictionaries; Electrodes; Electromyography; Encoding; Laboratories; Multidimensional systems; Muscles; Needles; Root mean square; Electromyogram (EMG); data compression; isometric contractions; Action Potentials; Algorithms; Data Compression; Electromyography; Humans; Isometric Contraction; Pattern Recognition, Automated; Reproducibility of Results; Sensitivity and Specificity; Signal Processing, Computer-Assisted;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2008.919729
  • Filename
    4545011