DocumentCode :
757496
Title :
New ZVS-PWM inverter switching limits and operating area
Author :
Metz, M. ; Roux, J. ; Doua, S. Ben ; Arches, J.P. ; Foch, H.
Author_Institution :
Inst. Nat. Polytech. de Toulouse, France
Volume :
139
Issue :
2
fYear :
1992
fDate :
3/1/1992 12:00:00 AM
Firstpage :
86
Lastpage :
95
Abstract :
Soft commutation (zero voltage switching or zero current switching (ZVS or ZCS)) allows high frequency operation of power static convertors, reduction of losses and parasitic interferences. The popular PWM inverter cannot naturally benefit from the soft commutation, but only slight changes are to be made to perform ZVS with a PWM inverter (equipped with its filter). A theoretical approach deals with power convertors using soft commutation and the resulting switching limits; it shows that only little restriction in the operating area is induced by these switching conditions. Experimental results on a MOS inverter and a GTO validate this analysis
Keywords :
invertors; pulse width modulation; switching; GTO thyristor; MOS inverter; ZVS-PWM inverter; operating area; soft commutation; switching limits; zero voltage switching;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings B
Publisher :
iet
ISSN :
0143-7038
Type :
jour
Filename :
121770
Link To Document :