• DocumentCode
    75884
  • Title

    Calculation Errors of the Electric Field Induced in a Human Body Under Quasi-Static Approximation Conditions

  • Author

    Sang Wook Park ; Wake, Kanako ; Watanabe, Shigetaka

  • Author_Institution
    Nat. Inst. of Inf. & Commun. Technol., Tokyo, Japan
  • Volume
    61
  • Issue
    5
  • fYear
    2013
  • fDate
    May-13
  • Firstpage
    2153
  • Lastpage
    2160
  • Abstract
    We analytically compute the internal electric fields in a spherical model and numerically calculate the fields in the head of a realistic human model exposed to the incident magnetic fields only or to both the incident electric and magnetic fields. We then investigate the effects of ignoring the electric fields incident on a biological object that is exposed to electromagnetic fields (EMFs) from an IF source, such as an induction hob or a wireless power transmission system, in which the magnetic fields are generally dominant. The induced electric fields inside a lossy dielectric sphere exposed to a plane wave are computed using rigorous formulas and quasi-static approximation (QSA) formulas. The highest frequency to which a QSA is valid and the difference made by ignoring the incident electric fields by varying the ratio of incident electric field intensity to incident magnetic field intensity (field impedance, E/H) are investigated through this computation. We also estimate the internal electric fields and specific absorption rates in the head of a Japanese adult male model exposed to EMFs or to magnetic fields only at 1 and 10 MHz with the finite-difference time-domain method, a full-wave analysis that takes both electric and magnetic fields into consideration, and the impedance method, a QSA calculation that takes only the magnetic fields into consideration. The E/H ratio must be lower than 17 Ω to ignore the electric fields incident on the sphere with errors of less than 5% from 10 Hz to 10 MHz. The difference made by ignoring the incident electric fields in the realistic head model is a little larger than that in the sphere model. The results suggest that we should carefully consider E/H to exactly evaluate the dosimetry.
  • Keywords
    bioelectric phenomena; biological effects of fields; biomagnetism; brain models; electromagnetic fields; finite difference time-domain analysis; muscle; radiation protection; EMF; IF source; QSA; dosimetry; electric field intensity; electromagnetic fields; finite-difference time-domain method; frequency 1 MHz; frequency 10 MHz; full-wave analysis; impedance method; induced electric fields; induction hob; internal electric fields; lossy dielectric sphere; magnetic field intensity; muscle tissue; quasistatic approximation conditions; realistic head model; specific absorption rates; wireless power transmission system; Computational modeling; Guidelines; Impedance measurement; Magnetic resonance imaging; Magnetic separation; Magnetosphere; Numerical models; Dosimetry; IF; Mie theory; finite-difference time-domain (FDTD) method; impedance method; quasi-static approximation (QSA);
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/TMTT.2013.2247211
  • Filename
    6472122