• DocumentCode
    758882
  • Title

    Detection and localization of inter-turn fault in the HV winding of a power transformer using wavelets [Comments and authors´ reply]

  • Author

    Gururaj, B.I. ; Satish, L.

  • Volume
    9
  • Issue
    3
  • fYear
    2002
  • fDate
    6/1/2002 12:00:00 AM
  • Firstpage
    479
  • Lastpage
    480
  • Abstract
    We discuss the paper by M.R. Rao and B.P. Singh (ibid. vol. 8, pp. 652-567, 2001) describing a wavelet approach for identification and localization of "minor" or "small" faults within HV transformer windings during lightning impulse tests on them. Although the authors\´ claim appear to be impressive, there are serious questions regarding the circuit models and computational procedures used, as well as, in the interpretation of the results obtained from the wavelet method. Therefore, the following is intended to obtain clarification from the authors and to help the reader with the usage of wavelets in addressing such problems
  • Keywords
    fault diagnosis; impulse testing; power transformer testing; transformer windings; waveform analysis; wavelet transforms; HV winding; fault localization; inter-turn fault detection; lightning impulse tests; neutral current analysis; power transformer; wavelet approach; Circuit faults; Circuit simulation; Circuit testing; Computational modeling; Fault detection; Fault diagnosis; Frequency; Impulse testing; Power transformers; Windings;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2002.1007712
  • Filename
    1007712