Title :
An Inexpensive Automatic Test System for Remote Supervision of Repeatered Lines
Author :
Nagaraj, K. ; Verma, J.K.
Author_Institution :
Indian Telephone Ind., Ltd., Bangalore, India
fDate :
7/1/1980 12:00:00 AM
Abstract :
Salient features of a novel automatic fault location scheme for remote supervision of repeatered digital transmission lines is discussed. Looping back repeaters in succession by a single command on the power feed line eliminates the use of a separate supervisory cable pair. The scheme has been generalized in such a way as to facilitate its adoption to almost all type of repeaters, thus providing an inexpensive,simple supervisory scheme for a low density rural area line transmission hookups.
Keywords :
Automatic testing; Communication system fault diagnosis; Digital communications; Wire communication repeaters; Automatic testing; Error analysis; Gaussian channels; Phase shift keying; Power cables; Power transmission lines; Repeaters; Signal to noise ratio; System testing; Transmission line theory;
Journal_Title :
Communications, IEEE Transactions on
DOI :
10.1109/TCOM.1980.1094759