DocumentCode
760576
Title
Improved Performance of Bayesian Solutions for Inverse Electrocardiography Using Multiple Information Sources
Author
Serinagaoglu, Y. ; Brooks, D.H. ; MacLeod, R.S.
Author_Institution
Dept. of Electr. & Electron. Eng., Middle East Tech. Univ., Ankara
Volume
53
Issue
10
fYear
2006
Firstpage
2024
Lastpage
2034
Abstract
The usual goal in inverse electrocardiography (ECG) is to reconstruct cardiac electrical sources from body surface potentials and a mathematical model that relates the sources to the measurements. Due to attenuation and smoothing that occurs in the thorax, the inverse ECG problem is ill-posed and imposition of a priori constraints is needed to combat this ill-posedness. When the problem is posed in terms of reconstructing heart surface potentials, solutions have not yet achieved clinical utility; limitations include the limited availability of good a priori information about the solution and the lack of a "good" error metric. We describe an approach that combines body surface measurements and standard forward models with two additional information sources: statistical prior information about epicardial potential distributions and sparse simultaneous measurements of epicardial potentials made with multielectrode coronary venous catheters. We employ a Bayesian methodology which offers a general way to incorporate these information sources and additionally provides statistical performance analysis tools. In a simulation study, we first compare solutions using one or more of these information sources. Then, we study the effects of varying the number of sparse epicardial potential measurements on reconstruction accuracy. To evaluate accuracy, we used the Bayesian error covariance as well as traditional error metrics such as relative error. Our results show that including even sparsely sampled information from coronary venous catheters can substantially improve the reconstruction of epicardial potential distributions and that a Bayesian framework provides a feasible approach to using this information. Moreover, computing the Bayesian error standard deviations offers a means to indicate confidence in the results even in the absence of validation data
Keywords
Bayes methods; bioelectric potentials; biomedical electrodes; catheters; electrocardiography; inverse problems; medical signal processing; signal reconstruction; statistical analysis; Bayesian error covariance; Bayesian solutions; body surface potentials; cardiac electrical source reconstruction; coronary venous catheters; epicardial potential distributions; heart surface potential reconstruction; inverse electrocardiography; multielectrode coronary venous catheters; multiple information sources; relative error; sparse epicardial potential measurements; standard forward models; statistical performance analysis tools; statistical prior information; Attenuation; Bayesian methods; Catheters; Electric variables measurement; Electrocardiography; Heart; Mathematical model; Smoothing methods; Surface reconstruction; Thorax; Bayesian estimation; forward/inverse modeling; inverse electrocardiography; inverse problems; Action Potentials; Algorithms; Bayes Theorem; Body Surface Potential Mapping; Computational Biology; Computer Simulation; Diagnosis, Computer-Assisted; Electrocardiography; Heart Conduction System; Humans; Models, Cardiovascular;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.2006.881776
Filename
1703754
Link To Document