Comparison measurements of currents induced by radiation and injection
Author :
Adams, John W. ; Cruz, Jose ; Melquist, Dean
Author_Institution :
Nat. Inst. of Stand. & Technol., Boulder, CO, USA
Volume :
34
Issue :
3
fYear :
1992
fDate :
8/1/1992 12:00:00 AM
Firstpage :
360
Lastpage :
362
Abstract :
Measurements that show significant differences between currents measured in individual wires of a bundle due to equal current excitations by external radiated fields or by bulk injection are reported. This raises concern whether bulk current injection is a reliable technique for EMC work
Keywords :
electric current measurement; electromagnetic compatibility; EMC; aircraft wiring; bulk injection; current excitations; current measurement; external radiated fields; individual wires; military aircraft; Aerospace electronics; Aircraft; Antenna measurements; Clamps; Current measurement; Electromagnetic compatibility; Radio frequency; Testing; Wires; Wiring;