DocumentCode
762463
Title
Preliminary pilot plant tests of a corona discharge-electron beam hybrid combustion flue gas cleaning system
Author
Chang, Jen-Shih ; Looy, Paul C. ; Nagai, Kazutoshi ; Yoshioka, Takeshi ; Aoki, Shinji ; Maezawa, Akihiko
Author_Institution
Dept. of Eng. Phys., McMaster Univ., Hamilton, Ont., Canada
Volume
32
Issue
1
fYear
1996
Firstpage
131
Lastpage
137
Abstract
Pilot power plant tests of a corona discharge-electron beam hybrid combustion flow gas cleaning system have been conducted. Gas flow rate of the test loop is a heavy oil fired boiler flue gas with 1200 Nm3 /h, and one electron beam generator (500 kV×30 mA) is used with a corona discharge ammonia radical injection system (60 kV×5 mA), SO2, CO, CO2, NH3, NO, NOx and O2 gases are monitored. The results show that up to 85% of NOx and 98% of SOx in flue gases are removed under a corona discharge-electron beam hybrid operations with significant small amount of leaked ammonias from exhaust flue gases
Keywords
air pollution; air pollution control; boilers; combustion; corona; electron beam applications; flue gas desulphurisation; pollution control; steam power stations; testing; 30 mA; 5 mA; 500 kV; 60 kV; 85 percent; 98 percent; CO; CO2; NH3; NO; NOx; O2; SO2; SOx; air emissions control; ammonia radical injection system; corona discharge-electron beam hybrid combustion; electron beam generator; exhaust flue gases; flue gas cleaning system; gas flow rate; heavy oil fired boiler; pilot tests; power plants; Boilers; Cleaning; Combustion; Corona; Electron beams; Flue gases; Fluid flow; Petroleum; Power generation; System testing;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/28.485824
Filename
485824
Link To Document