DocumentCode :
762623
Title :
Investigation of back-to-back starting of pumped storage hydraulic generating units
Author :
Konidaris, D.N.
Author_Institution :
Public Power Corp., Athens, Greece
Volume :
17
Issue :
2
fYear :
2002
fDate :
6/1/2002 12:00:00 AM
Firstpage :
273
Lastpage :
278
Abstract :
In the present paper, the procedure of back-to-back starting of pumped-storage hydraulic generating units is investigated and analyzed. The results from simulation as well as from real on-site measurements are presented and compared for a case study of a Greek power station. Main parameters influencing this phenomenon are analyzed, and information is given on the physical laws underlying the process. In particular, the effects of excitation and gate valve opening procedure are discussed, along with the torque-speed characteristic of the driving machine. Guidance is developed for the proper selection of the main parameters for a successful start
Keywords :
pumped-storage power stations; starting; torque; valves; Greek power station; back-to-back starting; excitation; gate valve opening procedure; on-site measurements; pumped storage hydraulic generating units; torque-speed characteristic; Circuit simulation; Frequency conversion; Hydroelectric power generation; Power generation; Power measurement; Pumps; Synchronous machines; Synchronous motors; Thermal stresses; Torque;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/TEC.2002.1009480
Filename :
1009480
Link To Document :
بازگشت