Title :
Matched interconnect design using ground-surrounded microstrip line
Author :
Khalaj-Amirhosseini, M. ; Cheldavi, A.
Author_Institution :
Coll. of Electr. Eng., Iran Univ. of Sci. & Technol., Narmark Tehran, Iran
Abstract :
A structure called a ground-surrounded microstrip line is introduced. This structure is a microstrip line surrounded by two strips grounded at some points along their lengths. This structure will be used to design matched G-S-G (ground-signal-ground) type interconnects (maximum delivered power to the main load in a wide frequency band).
Keywords :
integrated circuit interconnections; microstrip lines; ground-signal-ground type interconnects; ground-surrounded microstrip line; matched interconnect design; maximum power delivery; wide frequency band;
Journal_Title :
Circuits, Devices and Systems, IEE Proceedings -
DOI :