DocumentCode
764074
Title
Distributed energy store railgun: the limiting case
Author
Marshall, Richard A.
Author_Institution
WBM Stalker Pty. Ltd., Brisbane, Qld., Australia
Volume
27
Issue
1
fYear
1991
fDate
1/1/1991 12:00:00 AM
Firstpage
136
Lastpage
138
Abstract
When the limiting case of a distributed energy store railgun is analyzed, (i.e. the case where the space between adjacent energy stores become indefinitely small) three important results are obtained. First, the shape of current pulse delivered by each store is sinusoidal with an exponential tail. Secondly, the rail-to-rail voltage behind the rearmost active store approaches zero. Thirdly, it is not possible to choose parameters in such a way that capacitor crowbars can be eliminated
Keywords
electromagnetic launchers; energy storage; capacitor crowbars; current pulse; distributed energy store railgun; rail-to-rail voltage; Australia; Capacitance; Capacitors; Computer aided software engineering; Differential equations; Inductance; Railguns; Shape; Tail; Voltage;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.101009
Filename
101009
Link To Document