DocumentCode
764096
Title
Differential method against motion artefacts in skin conductance response measurement
Author
Lee, G. ; Choi, J.
Author_Institution
Sch. of Eng., Inf. & Commun. Univ., Daejeon
Volume
43
Issue
7
fYear
2007
Firstpage
375
Lastpage
377
Abstract
A differential method is proposed that can reduce motion artefacts in the bipolar measurement of skin conductance response. It is based on the fact that both the conductive and the capacitive currents across the skin are proportional to the contact area while only the conductive current reflects the sweat gland activity. Experimental results with a prototype system are presented
Keywords
bioelectric potentials; biomedical measurement; electric admittance measurement; skin; bipolar measurement; capacitive currents; conductive currents; contact area; motion artefacts; skin conductance response measurement; sweat gland activity;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:20073717
Filename
4145283
Link To Document