• DocumentCode
    765719
  • Title

    The use of contextual information in the reversible compression of medical images

  • Author

    Ramabadran, Tenkasi V. ; Chen, Keshi

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Iowa State Univ., Ames, IA, USA
  • Volume
    11
  • Issue
    2
  • fYear
    1992
  • fDate
    6/1/1992 12:00:00 AM
  • Firstpage
    185
  • Lastpage
    195
  • Abstract
    The authors investigate the use of conditioning events (or contexts) in improving the performances of known compression methods by building a source model with multiple contexts to code the decorrelated pixels. Three methods for reversible compression, namely DPCM (differential pulse code modulation), WHT (Walsh-Hadamard transform), and HINT (hierarchical interpolation), employing, respectively, predictive decorrelation, transform decorrelation, and multiresolution decorrelation, are considered. It is shown that the performance of these methods can be enhanced significantly, sometimes even up to 40%, by using contexts. The enhanced DPCM method is found to perform the best for MR and UT (ultrasound) medical images; the enhanced WHT method is found to be the best for X-ray images. The source models used in the enhanced models employ several hundred contexts
  • Keywords
    data compression; patient diagnosis; picture processing; Walsh-Hadamard transform; X-ray images; conditioning events; contextual information; differential pulse code modulation; hierarchical interpolation; medical images; multiresolution decorrelation; predictive decorrelation; reversible compression; source models; transform decorrelation; Biomedical imaging; Context modeling; Decorrelation; Huffman coding; Image coding; Image storage; Pixel; Predictive models; Pulse compression methods; Pulse modulation;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/42.141642
  • Filename
    141642