DocumentCode :
766695
Title :
EEG localization accuracy improvements using realistically shaped head models
Author :
Cuffin, B.Neil
Author_Institution :
Francis Bitter Nat. Magnet Lab., MIT, Cambridge, MA, USA
Volume :
43
Issue :
3
fYear :
1996
fDate :
3/1/1996 12:00:00 AM
Firstpage :
299
Lastpage :
303
Abstract :
A model of the head must be used in making estimates of the locations of electrical sources in the brain using electroencephalograms (EEGs) measured on the scalp. In part, the accuracy of these estimates is dependent on how accurately the model represents the actual head. In most work performed to date, spherical models of the head have been used. This paper presents results in which the estimates of source location are made in realistically shaped head models. Techniques for accurately and conveniently developing realistically shaped head models from CTs, MRIs, X-rays, and/or physical measurements are also presented. Realistically shaped head models are developed for three subjects with electrical sources implanted at known locations in the brain. Localization accuracy is found to be significantly better in the realistically shaped bead models than in spherical models if EEGs with good signal-to-noise ratio are used.
Keywords :
electroencephalography; physiological models; CT; EEG localization accuracy improvements; MRI; electrical sources location estimates; implanted electrical sources; physical measurements; radiography; realistically shaped head models; signal-to-noise ratio; spherical models; Brain modeling; Computer errors; Conductivity; Electric variables measurement; Electroencephalography; Humans; Magnetic heads; Noise measurement; Scalp; Shape measurement; Computer Simulation; Electrodes; Electroencephalography; Head; Humans; Models, Anatomic; Scalp;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/10.486287
Filename :
486287
Link To Document :
بازگشت