• DocumentCode
    767216
  • Title

    Realization and maintenance of the unit of capacitance with the PTB cross capacitor during the last ten years

  • Author

    Bachmair, Hans ; Funck, Torsten ; Hanke, Rüdiger ; Lang, Herbert

  • Author_Institution
    Physikalisch Tech. Bundesanstalt, Braunschweig, Germany
  • Volume
    44
  • Issue
    2
  • fYear
    1995
  • fDate
    4/1/1995 12:00:00 AM
  • Firstpage
    440
  • Lastpage
    442
  • Abstract
    A precise realization of the unit of capacitance is important for the determination of both the Josephson and the von Klitzing constants. The main design criteria of the PTB´s cross capacitor, the maintenance of the unit of capacitance over the last 10 years, and a special capacitance-measuring bridge for tracing back the electrode capacitance in the absolute volt experiment to SI units are described in this paper
  • Keywords
    capacitance measurement; capacitors; constants; units (measurement); Josephson constants; PTB cross capacitor; SI units; absolute volt experiment; capacitance measurement; capacitance-measuring bridge; design criteria; electrode capacitance; von Klitzing constants; Bridge circuits; Capacitance measurement; Capacitors; Electrodes; Fasteners; Probes; Proximity effect; Quantum capacitance; Uncertainty; Voltage;