DocumentCode :
767216
Title :
Realization and maintenance of the unit of capacitance with the PTB cross capacitor during the last ten years
Author :
Bachmair, Hans ; Funck, Torsten ; Hanke, Rüdiger ; Lang, Herbert
Author_Institution :
Physikalisch Tech. Bundesanstalt, Braunschweig, Germany
Volume :
44
Issue :
2
fYear :
1995
fDate :
4/1/1995 12:00:00 AM
Firstpage :
440
Lastpage :
442
Abstract :
A precise realization of the unit of capacitance is important for the determination of both the Josephson and the von Klitzing constants. The main design criteria of the PTB´s cross capacitor, the maintenance of the unit of capacitance over the last 10 years, and a special capacitance-measuring bridge for tracing back the electrode capacitance in the absolute volt experiment to SI units are described in this paper
Keywords :
capacitance measurement; capacitors; constants; units (measurement); Josephson constants; PTB cross capacitor; SI units; absolute volt experiment; capacitance measurement; capacitance-measuring bridge; design criteria; electrode capacitance; von Klitzing constants; Bridge circuits; Capacitance measurement; Capacitors; Electrodes; Fasteners; Probes; Proximity effect; Quantum capacitance; Uncertainty; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.377874
Filename :
377874
Link To Document :
بازگشت