• DocumentCode
    768613
  • Title

    The application of the bubble detector to the measurement of intense neutron fluences and energy spectra

  • Author

    Cousins, T. ; Tremblay, K. ; Ing, H.

  • Author_Institution
    Defence Res. Establ., Ottawa, Ont., Canada
  • Volume
    37
  • Issue
    6
  • fYear
    1990
  • fDate
    12/1/1990 12:00:00 AM
  • Firstpage
    1769
  • Lastpage
    1775
  • Abstract
    A novel type of bubble detector is developed which can measure neutron fluences on the order of 1011 n/cm2 (or a few grays). These detectors use superheated droplets which are much smaller than those in conventional bubble detectors. Preliminary studies involving several types of these microdroplet detectors having different neutron energy thresholds have been performed. The goal is to develop a set of such detectors which can be used as a simple neutron spectrometer needed in connection with TREE applications
  • Keywords
    bubble chambers; neutron detection and measurement; neutron spectroscopy; TREE applications; bubble detector; energy spectra; intense neutron fluences; microdroplet detectors; neutron energy thresholds; neutron spectrometer; superheated droplets; Detectors; Dosimetry; Electronic components; Energy measurement; Imaging phantoms; Neutrons; Rivers; Solids; Spectroscopy; Weapons;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.101190
  • Filename
    101190