DocumentCode :
769244
Title :
Investigation of different MicroCT scanner configurations by GEANT4 simulations
Author :
Khodaverdi, Maryam ; Chatziioannou, Arion F. ; Weber, Simone ; Ziemons, Karl ; Halling, Horst ; Pietrzyk, Uwe
Author_Institution :
Central Inst. for Electron., Forschungszentrum Jfilich GmbH, Julich, Germany
Volume :
52
Issue :
1
fYear :
2005
Firstpage :
188
Lastpage :
192
Abstract :
This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material.
Keywords :
X-ray spectra; bone; brain; cadmium compounds; caesium compounds; gadolinium compounds; phantoms; physics computing; positron emission tomography; selenium; CdZnTe; ClearPET; Crystal Clear Collaboration; CsI; GEANT4 simulations; Gd2O2S; Se; X-ray detectors; X-ray source; X-ray spectrum; X-ray tomography; air; aluminum filters; bone; brain; cadmium zinc telluride; cesium iodide; detector material; fat; gadolinium oxysulfide; microcomputed tomography scanner configurations; molybdenum source; phantom; selenium; small animal positron emission tomography system; tissues; tungsten source; water; Animals; Biological materials; Cadmium compounds; Collaboration; Crystalline materials; Positron emission tomography; Trademarks; X-ray detection; X-ray detectors; Zinc compounds; Cadmium Zinc Telluride (CZT); Cesium Iodide (CsI); ClearPET; GEANT4; Gadolinium Oxysulfide (GdOS); Selenium (Se); X-ray detectors; X-ray tomography; contrast;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2004.843098
Filename :
1417128
Link To Document :
بازگشت