Abstract
Several surface and volume rendering techniques are compared using nuclear medicine data including several new methods developed by the authors specifically for scintigraphic data. The techniques examined are summed projection, thresholded projection, threshold-based surface illumination, volumetric compositing, maximum-activity projection, sun-weighted maximum-activity projection, and variable attenuation. The advantages and disadvantages of each method are discussed in relation to the goals of three-dimensional display, which are defined herein. Selected images are shown to illustrate the usefulness of the methods
Keywords
radioisotope scanning and imaging; 3D display; medical diagnostic imaging; nuclear medicine; scintigraphic data; summed projection; surface rendering; threshold-based surface illumination; thresholded projection; volume rendering; volumetric compositing; Biomedical imaging; Humans; Image converters; Large-scale systems; Layout; Nuclear medicine; Radiology; Rendering (computer graphics); Three dimensional displays; Tomography;