• DocumentCode
    772375
  • Title

    A Fast-Slow Coincidence System Employing a Multichannel Time Display

  • Author

    Tomlinson, R.B. ; Brown, R.L.

  • Author_Institution
    Atomic Energy of Canada Limited Chalk River, Ontario, Canada
  • Volume
    11
  • Issue
    2
  • fYear
    1964
  • fDate
    4/1/1964 12:00:00 AM
  • Firstpage
    28
  • Lastpage
    38
  • Abstract
    A versatile, solid-state Fast-Slow Coincidence system is described which is used with large NaI(Tl) scintillators and XP1040 photomultipliers. A multichannel time display is provided which consists of a time-to-amplitude converter of the "start-stop" type and a standard 100-channel kicksorter. The calibration of the time analyzer can be varied from 1 nsec to 0.1 nsec per channel. In addition to showing the time spread, the display indicates the coincidence resolving time (2To) which is variable from 1 to 100 nsec by means of front panel helipots. The electronic time jitter of the system, as measured with a fast pulser is less than 0.2 nsec. A resolving time of 8 nsec gives 95% coincidence efficiency for coincidences between the annihilation radiation photo-22 peaks from Na22
  • Keywords
    Calibration; Delay effects; Detectors; Displays; Energy resolution; Photomultipliers; Pulse measurements; Rivers; Solid state circuits; Time measurement;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1964.4323383
  • Filename
    4323383