    Monitoring of polyethylene wear in nonmetal-backed acetubular cups by digitized anteroposterior pelvic radiography

  • Author

    Sarry, L. ; Tilmant, C. ; Boisgard, S. ; Boire, J.-Y. ; Levai, J.-P.

  • Author_Institution
    Fac. of Med., Auvergne Univ., Clermont-Ferrand, France
  • Volume
    22
  • Issue
    9
  • fYear
    2003
  • Firstpage
    1172
  • Lastpage
    1182
  • Abstract
    The aim of this study was to assess polyethylene wear in a total hip prosthesis by digitized radiography of the whole pelvis in the anteroposterior (AP) plane. The three-dimensional (3-D) pose of the nonmetal-backed acetubular cup, materialized by its metal ring and the femoral head made of metal or ceramic, was estimated using iterative algebraic algorithms with inner bias correction and bootstrapping for variance reduction. Points of interest were obtained by maximizing the correlation between sampled density profiles and 3-D geometric models degraded by the modulation transfer function (MTF) of the radiographic system and the film scanner. The error in the maximal correlation estimate were inferred from noise power spectra (NPS) and allowed the calculation of the point covariance matrix. Both NPS and MTF were modeled for each stage and estimated using least-square fitting of the overall NPS model to the autospectral density function calculated in stationary regions. Comparison of the radiographic time series was made possible by the high accuracy level and 3-D matching from the cup orientation. The feasibility of the full 3-D measurement, the assumption of negligible lateral wear and its influence on AP wear are discussed on simulated and real radiographic data.
  • Keywords
    biomedical materials; diagnostic radiography; image matching; medical image processing; orthopaedics; polymers; prosthetics; time series; wear testing; 3-D geometric models; autospectral density function; digitized anteroposterior pelvic radiography; femoral head; film scanner; lateral wear; least-square fitting; maximal correlation estimate error; medical diagnostic imaging; metal ring; modulation transfer function; nonmetal-backed acetubular cups; point covariance matrix calculation; polyethylene wear monitoring; radiographic system; real radiographic data; sampled density profiles; simulated radiographic data; three-dimensional pose; Ceramics; Hip; Iterative algorithms; Monitoring; Pelvis; Polyethylene; Power system modeling; Prosthetics; Radiography; Solid modeling; Acetabulum; Algorithms; Computer Simulation; Equipment Failure Analysis; Feasibility Studies; Hip Joint; Hip Prosthesis; Humans; Imaging, Three-Dimensional; Joint Instability; Metals; Pelvis; Phantoms, Imaging; Polyethylene; Prosthesis Failure; Radiographic Image Interpretation, Computer-Assisted; Reproducibility of Results; Sensitivity and Specificity;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2003.817017
  • Filename
    1225851