Title :
Evaluation of pulse voltage generators
Author :
Rea, Massimo ; Yan, Keping
Author_Institution :
Dept. of Electr. Eng., Padova Univ., Italy
Abstract :
In this paper, the electrical characteristics of the positive pulsed corona in a wire-cylinder type reactor are investigated. The injected energy and charge into the discharging volume per pulse and per unit length of corona emitting wire are adopted to evaluate the power source, electric circuits, and the corona wire. The discharging current lasts from several hundred nanoseconds to a few microseconds. The current, power peak values, and the injected energy and charge per pulse per unit length of emitting wire can reach up to 60 A/m, 5 MW/m, 480 mJ/m, and 8 μC/m, respectively. The energy conversion efficiency related to the output energy from the pulse forming capacitor and the energy delivered to the discharging volume can reach up to 90%. All results are obtained at room temperature and in air
Keywords :
corona; pulse generators; pulsed power technology; corona emitting wire; discharging volume per pulse; discharging volume per unit length; electric circuits; energy conversion efficiency; injected charge; injected energy; output energy; power peak values; power source; pulse forming capacitor; pulse voltage generators; wire-cylinder type reactor; Capacitors; Corona; Electric variables; Energy conversion; Inductors; Pulse circuits; Pulse generation; Temperature; Voltage; Wire;
Journal_Title :
Industry Applications, IEEE Transactions on