• DocumentCode
    773899
  • Title

    Digital Period Meter Utilizing Magnetic Core

  • Author

    Sakurai, Yoshifumi ; Inokuchi, Seiji

  • Author_Institution
    Department of Nuclear Engineering Osaka University, Osaka, Japan
  • Volume
    12
  • Issue
    1
  • fYear
    1965
  • Firstpage
    366
  • Lastpage
    373
  • Abstract
    A new type of reactor period meter utilizing multi-pulse magnetic counter as a neutron level comparator is described. The counter, which is initially counted for a unit interval at any time, is subtracted by one count for each input pulse after a fixed time-lag. The time required to empty the counter may be converted to reactor period by usage of a logic matrix. Ring ferrite cores are used as high speed shaping element and high speed pental counting element, and Deltamax core (50 Ni-Fe alloy) as decimal counting one. These pental and decimal counting circuits are originated from dividing the total magnetic flux amount (from negative to positive saturation) into 5 and 10 steps, respectively, and changing the flux level in the magnetic core stepwise corresponding to each input pulse. The period meter construction with magnetic cores results in increasing simplicity and reliability, and is much superior to the conventional circuit with a logarithmic amplifier and a differential circuit.
  • Keywords
    Counting circuits; Inductors; Logic; Magnetic circuits; Magnetic cores; Magnetic flux; Matrix converters; Neutrons; Pulse amplifiers; Saturation magnetization;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1965.4323537
  • Filename
    4323537