• DocumentCode
    776315
  • Title

    Beam Pulse Selector for a Sector Focused Cyclotron

  • Author

    Svanheden, A. ; Howe, H.A. ; Reiser, M.

  • Author_Institution
    U. S. Naval Radiological Defense Laboratory San Francisco, California 94135
  • Volume
    12
  • Issue
    3
  • fYear
    1965
  • fDate
    6/1/1965 12:00:00 AM
  • Firstpage
    977
  • Lastpage
    979
  • Abstract
    For the U. S. Naval Radiological Defense Laboratory\´s (NRDL) 70-inch sector-focused cyclotron a beam-pulse selector system has been developed by means of which an individual beam pulse or "fish" can be selected near the center of the machine and then accelerated to full energy and extraction. The beam is normally deflected axially into a beam stopper by a negative dc voltage of 10.5 kV applied to the deflector plates via a helically wound coaxial line of 2000 ohms characteristic impedance. An individual fish is transmitted by applying a 5.5 kV positive pulse of less than 40 nsec duration at the input of the coaxial line.
  • Keywords
    Acceleration; Coaxial components; Cyclotrons; Frequency; Impedance; Laboratories; Marine animals; Particle beams; Voltage; Wounds;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1965.4323772
  • Filename
    4323772