Abstract :
X-pinches have been developed as point sources of soft X-rays for radiography, and are now routinely used for that purpose. Spatial resolution as good as 2 μm and time resolution as good as a few 10 s of picoseconds has been obtained. Here, we present images from one of a very small number of tests in which a 450-kA, 100-ns pulse was divided among three X-pinches in parallel, and each of the three emitted an X-ray burst that was used for radiography of one or both of the other two.
Keywords :
Z pinch; plasma diagnostics; 10 s; 100 ns; 2 mum; 450 kA; X-ray burst; radiographic images; soft X-rays; time-dependent X-pinch structure; Optical imaging; Plasma sources; Plasma x-ray sources; Power generation; Pulse generation; Pulse shaping methods; Radiography; Spatial resolution; Testing; Timing; Exploding-wire z-pinch; X-pinch plasma; X-ray radiography;