DocumentCode
777640
Title
Neutron and Gamma Sensitivities of Dynamic Detectors
Author
Martin, J.A. ; Shatzkes, M. ; Kloepper, R.M.
Volume
12
Issue
5
fYear
1965
Firstpage
101
Lastpage
111
Abstract
The neutron and gamma sensitivities of nine detectors were studied in experiments performed at the Sandia Pulsed Reactor (SPR). Of the detectors tested, six are predominantly gamma detectors at the SPR and three produce a significant fraction of their total current due to the neutron flux during a normal SPR burst. None of the detectors studied were found to be predominantly sensitive to the neutron flux during a normal SPR burst. Tests performed at pure gamma sources on a P-Intrinsic-N (PIN) diode detector are also described. The neutron induced current in the silicon detectors is treated theoretically.
Keywords
Electronic equipment testing; Gamma ray detection; Gamma ray detectors; History; Inductors; Neutrons; Performance evaluation; Pulse measurements; Radiation detectors; Radiation effects;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1965.4323905