DocumentCode :
777640
Title :
Neutron and Gamma Sensitivities of Dynamic Detectors
Author :
Martin, J.A. ; Shatzkes, M. ; Kloepper, R.M.
Volume :
12
Issue :
5
fYear :
1965
Firstpage :
101
Lastpage :
111
Abstract :
The neutron and gamma sensitivities of nine detectors were studied in experiments performed at the Sandia Pulsed Reactor (SPR). Of the detectors tested, six are predominantly gamma detectors at the SPR and three produce a significant fraction of their total current due to the neutron flux during a normal SPR burst. None of the detectors studied were found to be predominantly sensitive to the neutron flux during a normal SPR burst. Tests performed at pure gamma sources on a P-Intrinsic-N (PIN) diode detector are also described. The neutron induced current in the silicon detectors is treated theoretically.
Keywords :
Electronic equipment testing; Gamma ray detection; Gamma ray detectors; History; Inductors; Neutrons; Performance evaluation; Pulse measurements; Radiation detectors; Radiation effects;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1965.4323905
Filename :
4323905
Link To Document :
بازگشت