    Effect of a cylindrical refracting interface on ultrasound intensity and the CW Doppler spectrum

  • Author

    Thompson, Rosemary S. ; Aldis, Geoffrey K.

  • Author_Institution
    Sch. of Math. & Stat., Sydney Univ., NSW, Australia
  • Volume
    43
  • Issue
    5
  • fYear
    1996
  • fDate
    5/1/1996 12:00:00 AM
  • Firstpage
    451
  • Lastpage
    459
  • Abstract
    The insonation of axisymmetric flow in a tube by an ultrasound beam which is refracted at the tube surface is considered. A three-dimensional (3-D) model for refraction at a cylindrical interface is developed. The incident beam, which is planar but otherwise arbitrary, is refracted at a single acoustic impedance interface between the medium within the tube and the surrounding medium. A ray approximation is used as the ultrasonic wavelength is small compared to the radius of curvature of the tube. A parametric form for the ray paths is obtained and used to derive an expression for the intensity. The intensity depends on the specific position within the tube, as well as the ratio of sound speeds, N, and the Doppler angle θ D. A diverging (N=1.2, θ D=45°) and a converging (N=0.8, θ D=45°) case are presented in detail. The converging interface results in more extreme intensity distortion. The regions of maximum and minimum intensity over a tube slice are immediately adjacent in both diverging and converging cases. Once the intensity distribution across a tube slice is known, the previously reported (Aldis and Thompson, 1992) volume integral method for the calculation of continuous wave (CW) Doppler spectral power density (spd) functions may be used. The effect of refraction of the incident beam on the spd function is shown for both an infinite beam and a circular beam with radius equal to the tube radius. A curved acoustic impedance interface, as may be encountered in vitro in flow phantoms or in vivo in vascular disease, leads to nonuniform insonation and spectral distortion which depends on transducer orientation.
  • Keywords
    Doppler measurement; biomedical ultrasonics; blood flow measurement; physiological models; ultrasonic refraction; Doppler angle; Doppler spectral power density; axisymmetric flow insonation; cylindrical refracting interface; flow phantoms; intensity distortion; nonuniform insonation; ray approximation; ray paths; sound speed; spectral distortion; transducer orientation; tube slice; ultrasonic wavelength; vascular disease; volume integral method; Acoustic beams; Acoustic distortion; Acoustic refraction; Diseases; Imaging phantoms; In vitro; In vivo; Surface acoustic waves; Surface impedance; Ultrasonic imaging; Animals; Biophysics; Blood; Blood Flow Velocity; Humans; Models, Cardiovascular; Ultrasonography, Doppler;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.488793
  • Filename
    488793