Title :
Reliability assessment of fielded plastic and hermetically packaged microelectronics
Author :
Johnson, Bruce ; Verma, Vani
Author_Institution :
Honeywell Inc., Minneapolis, MN, USA
fDate :
3/1/1996 12:00:00 AM
Abstract :
This paper presents the results from multiple studies at Honeywell, of piece-part failure rates experienced in field use. These studies consider 7 line-replaceable-units (LRU), containing either hermetically sealed microcircuits (HSM) or plastic encapsulated microcircuits (PEM) or both. This paper compares the resulting field failure rates (λ) of HSM and PEM: digital devices: λPEM≈0.5λHSM; linear devices: λPEM≈3λHSM; only a small fraction of the linear devices degraded in performance at 125°C, though their performance at room temperature was within specification. The latter two points suggest that linear devices might require more attention relative to characterization over temperature and application considerations than do digital devices
Keywords :
analogue integrated circuits; digital integrated circuits; encapsulation; failure analysis; integrated circuit reliability; plastic packaging; Honeywell; digital devices; hermetically packaged microelectronics; line-replaceable-units; linear devices; piece-part failure rates; plastic packaged microelectronics; reliability assessment; room temperature performance; Electronics packaging; Hermetic seals; Large scale integration; Microelectronics; Plastic packaging; Power supplies; Qualifications; Temperature sensors; Testing; Transmitters;
Journal_Title :
Reliability, IEEE Transactions on