DocumentCode
778829
Title
Reliability assessment of fielded plastic and hermetically packaged microelectronics
Author
Johnson, Bruce ; Verma, Vani
Author_Institution
Honeywell Inc., Minneapolis, MN, USA
Volume
45
Issue
1
fYear
1996
fDate
3/1/1996 12:00:00 AM
Firstpage
23
Lastpage
26
Abstract
This paper presents the results from multiple studies at Honeywell, of piece-part failure rates experienced in field use. These studies consider 7 line-replaceable-units (LRU), containing either hermetically sealed microcircuits (HSM) or plastic encapsulated microcircuits (PEM) or both. This paper compares the resulting field failure rates (λ) of HSM and PEM: digital devices: λPEM≈0.5λHSM; linear devices: λPEM≈3λHSM; only a small fraction of the linear devices degraded in performance at 125°C, though their performance at room temperature was within specification. The latter two points suggest that linear devices might require more attention relative to characterization over temperature and application considerations than do digital devices
Keywords
analogue integrated circuits; digital integrated circuits; encapsulation; failure analysis; integrated circuit reliability; plastic packaging; Honeywell; digital devices; hermetically packaged microelectronics; line-replaceable-units; linear devices; piece-part failure rates; plastic packaged microelectronics; reliability assessment; room temperature performance; Electronics packaging; Hermetic seals; Large scale integration; Microelectronics; Plastic packaging; Power supplies; Qualifications; Temperature sensors; Testing; Transmitters;
fLanguage
English
Journal_Title
Reliability, IEEE Transactions on
Publisher
ieee
ISSN
0018-9529
Type
jour
DOI
10.1109/24.488911
Filename
488911
Link To Document