• DocumentCode
    782137
  • Title

    Outdoor leakage current monitoring of silicone composite insulators in coastal service conditions

  • Author

    Vlastós, Antonios E. ; Orbeck, Tor

  • Author_Institution
    Chalmers Univ. of Technol., Goteborg, Sweden
  • Volume
    11
  • Issue
    2
  • fYear
    1996
  • fDate
    4/1/1996 12:00:00 AM
  • Firstpage
    1066
  • Lastpage
    1070
  • Abstract
    The behavior of the polymeric insulators under salt-storm conditions is crucial for their design. In this paper the leakage currents monitored on silicone composite insulators during two severe salt-storms on the Swedish West Coast are analyzed. The results show that reduction of the leakage distance on silicone rubber units causes considerable dry-band arc activity
  • Keywords
    arcs (electric); composite insulating materials; composite insulators; electric current measurement; insulator testing; leakage currents; monitoring; silicone rubber; silicone rubber insulators; Swedish West Coast; coastal service conditions; data acquisition system; dry-band arc activity; leakage distance reduction; outdoor leakage current monitoring; polymeric insulators; salt-storm conditions; severe salt-storms; silicone composite insulators; Condition monitoring; Leakage current; Monitoring; Plastic insulation; Pollution; Polymers; Porcelain; Rubber; Sea measurements; Surface contamination; Surface discharges;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/61.489369
  • Filename
    489369