DocumentCode
782947
Title
In-Core Instrumentation and Fast Digital Data Acquisition for the Sefor Nuclear Test Reactor
Author
Glauner, H.W. ; Pflasterer, G.P. ; Momberger, J.F.
Author_Institution
Gesellschaft fuer Kernforschung, Karlsruhe, Germany
Volume
14
Issue
1
fYear
1967
Firstpage
293
Lastpage
299
Abstract
The primary purpose of the SEFOR nuclear test reactor is to measure the dynamic behavior of a fast reactor core. Special in-core instrumentation has been developed for fuel and sodium temperature and sodium flow rate measurements. Neutron detectors have been built and tested which will measure reactor power peaks up to 106 MW. A fast computer-controlled data acquisition system allows sampling rates up to 30,000 data/sec. The system provides for minor data reduction and analysis.
Keywords
Data acquisition; Detectors; Fluid flow measurement; Fuels; Inductors; Neutrons; Nuclear measurements; Reactor instrumentation; Temperature; Testing;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1967.4324430
Filename
4324430
Link To Document