DocumentCode :
782956
Title :
An investigation of dual energy transmission measurements in simultaneous transmission emission imaging
Author :
Welch, Andy ; Gullberg, Grant T. ; Christian, Paul E. ; Li, Jia ; Tsui, Benjamin M W
Author_Institution :
Med. Imaging Res. Lab., Utah Univ., Salt Lake City, UT, USA
Volume :
42
Issue :
6
fYear :
1995
fDate :
12/1/1995 12:00:00 AM
Firstpage :
2331
Lastpage :
2338
Abstract :
In this study we investigate the feasibility of acquiring dual energy transmission projection data using a conventional gamma camera. Transmission projection data are acquired, simultaneously with 99m Tc emission data, using the two major photopeaks of 153Gd, at 44 keV and 99 keV. The degree of contamination of the data in the 44 keV window, by scattered 99 keV transmission photons, is investigated using Monte Carlo simulations. A modified scaling method is proposed to convert the two attenuation maps, obtained from transmission data acquired at 44 keV and 99 keV, to one appropriate for 99mTc. This attenuation map is compared to one produced by scaling the 99 keV attenuation map, for the attenuation correction of 99mTc SPECT images. The use of dual energy transmission imaging is shown to improve the quantitative accuracy of the reconstructed SPECT images compared to a single scale factor method. However, for situations where a dual scaling factor method is possible, this is shown to perform as well as the dual energy method. Dual energy transmission imaging is shown to be more effective at visualizing areas of bone, particularly in regions near the edge of the untruncated field of view
Keywords :
Monte Carlo methods; bone; single photon emission computed tomography; 44 keV; 99 keV; 153Gd; 99mTc; Gd; Monte Carlo simulations; Tc; attenuation correction; attenuation maps; bone areas visualization; contamination; dual energy method; dual energy transmission measurements; dual energy transmission projection data; gamma camera; photopeaks; reconstructed SPECT images; scaling method; simultaneous transmission emission imaging; single photon emission computed tomography; single scale factor method; transmission photons; transmission projection data; Attenuation; Cameras; Contamination; Electromagnetic scattering; Energy measurement; Image reconstruction; Particle scattering; Pollution measurement; Single photon emission computed tomography; Visualization;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.489437
Filename :
489437
Link To Document :
بازگشت