• DocumentCode
    783020
  • Title

    The Design and Performance of a 1200°F Magnetic Flowmeter for In-Core Application in Sodium-Cooled Reactors

  • Author

    Popper, G.F. ; Glass, M.C.

  • Author_Institution
    Argonne National Laboratory Argonne, Illinois
  • Volume
    14
  • Issue
    1
  • fYear
    1967
  • Firstpage
    342
  • Lastpage
    347
  • Abstract
    A magnetic flowmeter that may be used in the core of a 1200°F sodium-cooled reactor has been designed and partially tested, The flowmeter is constructed in the shape of a hexagon so that it can be completely self-contained as a part of a reactor fuel element. An integral stainless steel sheath, alumina insulated, stainless steel lead wire is provided for signal transmission. Complete construction and design details are presented. The effects of temperature and nuclear radiation on the magnet stability are considered and discussed. The preliminary test results are given and compared to the calculated performance.
  • Keywords
    Automatic testing; Cable insulation; Fuels; Inductors; Magnetic cores; Shape; Stability; Steel; Temperature; Wire;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1967.4324437
  • Filename
    4324437