• DocumentCode
    784560
  • Title

    Improved implementation of four-standard procedure for calibrating six-port reflectometers

  • Author

    Qiao, L. ; Yeo, S.P.

  • Author_Institution
    Dept. of Electr. Eng., Nat. Univ. of Singapore, Singapore
  • Volume
    44
  • Issue
    3
  • fYear
    1995
  • fDate
    6/1/1995 12:00:00 AM
  • Firstpage
    632
  • Lastpage
    636
  • Abstract
    The present paper describes an improved version of a four-standard calibration procedure for six-port reflectometers that utilizes simple iteration computations instead of the other more cumbersome optimization techniques attempted previously. The four standards required are a matched load (with a return loss not more than -40 dB) and three highly reflecting terminations (each with a return loss not less than -2 dB)
  • Keywords
    calibration; iterative methods; measurement standards; microwave reflectometry; reflectometers; -2 dB; -40 dB; calibration; four-standard procedure; iteration; matched load; optimization; reflecting terminations; return loss; six-port reflectometers; Calibration; Detectors; Hardware; Instruments; Measurement standards; Nonlinear equations; Particle measurements; Reflection; Software standards; Testing;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.387297
  • Filename
    387297