• DocumentCode
    7851
  • Title

    Motion of the Kidney Between Preoperative and Intraoperative Positioning

  • Author

    Schneider, C. ; Nguan, Christopher ; Longpre, M. ; Rohling, Robert ; Salcudean, Septimiu

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of British Columbia, Vancouver, BC, Canada
  • Volume
    60
  • Issue
    6
  • fYear
    2013
  • fDate
    Jun-13
  • Firstpage
    1619
  • Lastpage
    1627
  • Abstract
    For many laparoscopic surgical procedures, the preoperative images are taken with the patient in a different position than that in which the surgery is performed. The organ shift between positions can affect surgical image guidance, as the organ shifts can complicate image registration. In particular, for partial nephrectomy, the standard clinical approach requires supine preoperative computed tomography, while the surgery is performed in the flank position. We studied ten subjects in both supine and flank positions. Rigid registration was used to determine the relative motion of the kidneys, using the spine as a pose-independent landmark. Our results showed that the kidney can move as much as 46.5 mm as a result of a supine-to-flank change in patient position, and rotate as much as 25°. From the results, significant kidney motion occurs due to the change of patient position from supine to flank. These changes warrant further study to understand and model the patient specific motion.
  • Keywords
    computerised tomography; endoscopes; image motion analysis; image registration; kidney; medical image processing; surgery; flank position; image registration; intraoperative positioning; kidney motion; laparoscopic surgical procedures; organ shifts; partial nephrectomy; pose-independent landmark; preoperative images; preoperative positioning; standard clinical approach; supine preoperative computed tomography; supine-to-flank change; surgical image guidance; Computed tomography; Kidney; Liver; Magnetic resonance imaging; Surgery; Tumors; Anatomical structure; image registration; kidney; surgery; Adult; Aged; Female; Humans; Image Processing, Computer-Assisted; Intraoperative Care; Kidney; Laparoscopy; Male; Middle Aged; Movement; Patient Positioning; Posture; Surgery, Computer-Assisted; Tomography, X-Ray Computed;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2013.2239644
  • Filename
    6410004